  1. CISA Adds One Known Exploited Vulnerability to Catalog (CVE-2026-64849) โ€” Yes, if you run MLflow versions 1.20.0 - 1.23.2: active exploitation of SSRF vulnerability can lead to total control of the asset.
  2. Defending Against an Active Threat to Siemens S7 Series PLCs โ€” Yes, if you run Siemens S7 Series PLCs: active threat using AI-generated scripts to exploit outdated or poorly protected devices.

Everything else can wait.

๐Ÿ”ต 15 items on the radar โ€” see below โ†“


Why Should I Care? ๐Ÿ”ด HIGH โ€” Handle Now


CISA Adds One Known Exploited Vulnerability to Catalog

CISA Advisories [CISA KEV] | CVSS 8.6 | CVE-2026-64849

โ“ Why Should I Care?
Yes, if you run MLflow versions 1.20.0 - 1.23.2: active exploitation of SSRF vulnerability can lead to total control of the asset.

๐ŸŽฏ Affected versions: MLflow 1.20.0 - 1.23.2
Not affected: MLflow versions prior to 1.20.0 and 1.23.3 and later

๐ŸŽญ In plain English:
An attacker can trick your MLflow server into making requests to internal systems, potentially giving them full control over your server. For example, an attacker could use this to access sensitive data or execute commands on your internal network.

๐Ÿ”ง Prerequisites:

  • MLflow server must be accessible from the internet or an attacker-controlled network
  • Internal systems must be reachable from the MLflow server

โฑ Urgency: High urgency due to active exploitation in the wild.

๐Ÿ’ก Context: The SSRF vulnerability arises from MLflow's insecure handling of URLs, allowing attackers to craft malicious requests that the server will execute.

โœ… Fixed in: 1.23.3, 1.24.0


Defending Against an Active Threat to Siemens S7 Series PLCs

CISA Advisories

โ“ Why Should I Care?
Yes, if you run Siemens S7 Series PLCs: active threat using AI-generated scripts to exploit outdated or poorly protected devices. Immediate action required.

๐ŸŽฏ Affected versions: All Siemens S7 Series PLCs (S7-200, S7-300, S7-400, S7-1200, S7-1500 series)

๐ŸŽญ In plain English:
Your industrial control system (ICS) could be compromised by attackers using AI-generated scripts disguised as legitimate monitoring tools. They can disrupt critical processes, cause safety incidents, damage equipment, and steal sensitive data. For example, an attacker could remotely shut down your manufacturing line or alter the settings of your machinery, leading to potential safety hazards and financial losses.

๐Ÿ”ง Prerequisites:

  • PLCs are accessible from the Internet
  • Outdated software or poor protection

โฑ Urgency: High urgency due to active exploitation in the wild targeting U.S. critical infrastructure sectors.

๐Ÿ’ก Context: Threat actors are leveraging Internet scanning services to find and exploit vulnerabilities in Siemens S7 Series PLCs.


Why Should I Care? ๐ŸŸก MEDIUM (0)

None.


Why Should I Care? ๐Ÿ”ต On the Radar (21)


โšช 240 low-priority items filtered.


๐Ÿฆ… Aggregated and triaged by Donna AI  |  Sources: 9 vendor feeds  |  CISA KEV

Read more

Why Should I Care? โ€” 2026-09-24 | ๐Ÿ”ด 0 HIGH ยท ๐ŸŸก 0 MEDIUM ยท ๐Ÿ”ต 27 RADAR ยท โšช 69 FILTERED

๐Ÿ“‹ Briefing โ€” 2026-09-24 27 vendor intel items scanned ย |ย  ๐Ÿ”ด 0 HIGH ย |ย  ๐ŸŸก 0 MEDIUM ย |ย  ๐Ÿ”ต 27 RADAR ย |ย  โšช 69 FILTERED โœ… No critical items today. Everything else can wait. ๐Ÿ”ต 15 items on the radar โ€” see below โ†“ Why Should I Care? ๐Ÿ”ด HIGH โ€” Handle Now No HIGH priority items in the last 24h. Why Should I Care? ๐ŸŸก MEDIUM

By Josip Sokolovic

Why Should I Care? โ€” 2026-09-23 | ๐Ÿ”ด 5 HIGH ยท ๐ŸŸก 3 MEDIUM ยท ๐Ÿ”ต 27 RADAR ยท โšช 69 FILTERED

๐Ÿ“‹ Briefing โ€” 2026-09-23 35 vendor intel items scanned ย |ย  ๐Ÿ”ด 5 HIGH ย |ย  ๐ŸŸก 3 MEDIUM ย |ย  ๐Ÿ”ต 27 RADAR ย |ย  โšช 69 FILTERED ๐Ÿ”ด Critical โ€” action required: 1. CISA Adds Four Known Exploited Vulnerabilities to Catalog (CVE-2026-85102, CVE-2026-93616, CVE-2026-93952, CVE-2026-94127) โ€” Yes, if you run any affected versions of Check Point, Arista VeloCloud Orchestrator, or F5 BIG-IP APM: these vulnerabilities

By Josip Sokolovic

Why Should I Care? โ€” 2026-09-22 | ๐Ÿ”ด 1 HIGH ยท ๐ŸŸก 0 MEDIUM ยท ๐Ÿ”ต 17 RADAR ยท โšช 66 FILTERED

๐Ÿ“‹ Briefing โ€” 2026-09-22 18 vendor intel items scanned ย |ย  ๐Ÿ”ด 1 HIGH ย |ย  ๐ŸŸก 0 MEDIUM ย |ย  ๐Ÿ”ต 17 RADAR ย |ย  โšช 66 FILTERED ๐Ÿ”ด Critical โ€” action required: 1. CISA Adds One Known Exploited Vulnerability to Catalog (CVE-2026-7273) โ€” Yes, if you run Zyxel GS1900 Series Switches: This vulnerability can allow attackers to take full control of your switch. Everything else

By Josip Sokolovic

Why Should I Care? โ€” 2026-09-21 | ๐Ÿ”ด 23 HIGH ยท ๐ŸŸก 32 MEDIUM ยท ๐Ÿ”ต 209 RADAR ยท โšช 73 FILTERED

๐Ÿ“‹ Briefing โ€” 2026-09-21 264 vendor intel items scanned ย |ย  ๐Ÿ”ด 23 HIGH ย |ย  ๐ŸŸก 32 MEDIUM ย |ย  ๐Ÿ”ต 209 RADAR ย |ย  โšช 73 FILTERED ๐Ÿ”ด Critical โ€” action required: 1. CISA Adds One Known Exploited Vulnerability to Catalog (CVE-2026-76461) โ€” Yes, if you run Cisco Secure Email Gateway versions 12.0.0 - 12.0.4: SQL injection vulnerability, actively exploited in

By Josip Sokolovic